Oil Immersed Transformer
Total solution from design to delivery, installation & Commission.
We take pleasure in introducing ourselves as one of the leading manufacturer of TRANSFORMERS for over 42 years with experience in design, manufacturing, installation & commission of Power, Distribution, Cast Resin, Furnace, Earthing & Generator transformers. Mampower expert R&D team develops one of the most advanced designs to withstand short-circuit and impulse voltage tests.
It is our commitment to provide you customize transformer as per your requirement with world class quality & economical price.
Power & Distribution Transformer
Salient Features
|
|
Power Transformer
Technical Parameter |
Unit |
|
Applied Standard |
|
IEC - 60076 |
Type |
|
Outdoor |
Power Rating |
MVA |
Up to 20MVA |
Number of Phases |
|
3/ customer requirement |
Rated Voltage, Phase to Phase |
||
High Voltage Winding |
kV |
36/customer requirement |
Low Voltage Winding |
kV |
12/customer requirement |
Rated Frequency |
Hz |
50 |
Rated Insulation Level |
||
Impulse Withstand, Full Wave |
||
High Voltage Winding |
kV |
170 |
Low Voltage Winding |
kV |
75 |
Neutral Side |
|
Fully insulated |
AC Withstand Voltage |
||
High Voltage Winding |
kV |
70 |
Low Voltage Winding |
kV |
28 |
Impedance Voltage at 75°C and at Nominal Ratio and 100% Rated Power |
% |
As per IEC 60076-5/ customer requirement |
Vector Diagram (IEC 60076-4) |
|
Dyn1/Dyn11/Ynd11/Ynd1/customer requirement |
Type of Cooling |
|
ONAN/ONAF |
On load Tap- changer |
||
Type |
|
With oil/ vacuum switches |
Rated Tap |
kV |
36 |
Tapping Range Capacity |
% |
(+5% to -15)% / customer requirement |
Positions |
9/17/ customer requirement |
|
Temperature Rise at Rated Power |
||
Oil by Thermometer |
deg. C |
55 |
Winding by Resistance Measurement |
deg. C |
60 |
Transformer Looses |
|
|
Core Loss and Rated Voltage at Rated Frequency at Nominal Tap |
Watts |
As per design/Customer requirement |
Copper Loss at Full Load, at Rated Frequency |
Watts |
As per design/Customer requirement |
|
|
|
Overall Dimension |
mm |
As per design |
Overall Weight |
kg |
As per design |
Transport Weight |
kg |
As per design |
Distribution Transformer
Technical Specification for
Oil Filled Distribution Transformer up to36KV,5000KVA
Technical Parameter |
Unit |
|
Applied Standard |
|
IEC - 60076 |
Type |
|
Outdoor/Indoor |
Power Rating |
MVA |
Up to 5000KVA |
Number of Phases |
|
3/ customer requirement |
Rated Voltage, Phase to Phase |
||
High Voltage Winding |
kV |
33/11/6.35/customer requirement |
Low Voltage Winding |
V |
11/415/240 customer requirement |
Rated Frequency |
Hz |
50 |
Rated Insulation Level |
||
Impulse Withstand, Full Wave |
||
High Voltage Winding |
kV |
170/75/60 |
Low Voltage Winding |
kV |
- |
Neutral Side |
|
Fully insulated |
AC Withstand Voltage |
||
High Voltage Winding |
kV |
70/28/20 |
Low Voltage Winding |
kV |
28/3 |
Impedance Voltage at 75°C and at Nominal Ratio and 100% Rated Power |
% |
As per IEC 60076-5/ customer requirement |
Vector Diagram (IEC 60076-4) |
|
Dyn1/Dyn11/Ynd11/Ynd11/customer requirement |
Type of Cooling |
|
ONAN/ONAF/customer requirement |
Tap- changer |
||
Off load Tap- changer |
||
Rated voltage |
KV |
12 |
Tapping Range |
% |
+2.5% to -7.5%/+5% to -5%/+10% to -10%/ customer requirement |
|
position |
5/7/ customer requirement |
On load Tap- changer |
|
|
Type |
|
With oil/ vacuum switches |
Rated voltage |
kV |
12 |
|
|
|
Tapping Range Capacity |
% |
(+5% to -15)% / customer requirement |
Positions |
9/17 or higher |
|
Temperature Rise at Rated Power |
||
Oil by Thermometer |
deg. C |
55 |
Winding by Resistance Measurement |
deg. C |
60 |
Transformer Looses |
|
|
Core Loss and Rated Voltage at Rated Frequency at Nominal Tap |
Watts |
As per design/Customer requirement |
Copper Loss at Full Load, at Rated Frequency |
Watts |
As per design/Customer requirement |
|
|
|
Overall Dimension |
mm |
As per design |
Overall Weight |
kg |
As per design |
Transport Weight |
kg |
As per design |
Cast Resin Transformer (CRT):
Salient Features:
- Self-extinguishing characteristics in case of fair
- Compact and environment friendly
- Easy installation
- Maintenance free
- Designed to withstand the highest short circuit stress that may occur during operation
- High voltage coil windings are cast to prevent humidity
- High resistance against overvoltage
- Low decibel, high capacity and high performance
- Low partial discharge
- ENVIRONMENTALCLASS:E3
-
Transformers suitablefor heavy pollution areawith humidity above 95%
- CLIMATICCLASS: C2
-
Transformers suitable for operation,transport and storage
with ambient temperatures down to -25°c - FIRE BEHAVIORCLASS: F1
-
Transformers suitable for areaswith high risk of firebeing self-extinguishing
Technical Specification for
Cast Resin Transformer (CRT) up to 36KV, 30MVA KVA
Technical Parameter |
Unit |
|
Applied Standard |
|
IEC - 60076 |
Type |
|
Indoor |
Power Rating |
MVA |
Up to 30MVA |
Number of Phases |
|
3 |
Rated Voltage, Phase to Phase |
||
High Voltage Winding |
kV |
33/11/customer requirement |
Low Voltage Winding |
V |
11/415/240 customer requirement |
Rated Frequency |
Hz |
50 |
Rated Insulation Level |
||
Impulse Withstand, Full Wave |
||
High Voltage Winding |
kV |
As per IEC 60076-13 |
Low Voltage Winding |
kV |
|
Neutral Side |
|
Fully insulated |
AC Withstand Voltage |
||
High Voltage Winding |
kV |
As per IEC 60076-13 |
Low Voltage Winding |
kV |
|
|